Datex Ohmeda Direct-Connect SpO2 Sensors Alternative to TS-W4-H, Compatible

Datex Ohmeda Direct-Connect SpO2 Sensors Alternative to TS-W4-H, Compatible

SKU: S810-020
$160.00Price
Aftermarket Replacement Reusable Multi-Site
Quantity
  • Product Description

    Direct-Connect SpO2 sensor designed for multi-site monitoring, compatible with Datex patient monitors and suitable as an alternative to OEM reference TS-W4-H. This aftermarket replacement multi-site sensor provides stable oxygen saturation readings, reliable signal quality, and durable performance for continuous use in hospital and clinical environments.
  • OEM Part Number Cross References:

    Vendor OEM Part Numbers
    Cables and Sensors S810-020
    Datex Ohmeda TS-W4-H
  • Compatibility:

    Manufacturer Model Unit
    Datex Ohmeda
    • Datex Ohmeda 3700
    • Datex Ohmeda 3710
    • Datex Ohmeda 3740
    • Datex Ohmeda 3770
    • Datex Ohmeda 3775
    • Datex Ohmeda 37xx Series
    • Datex Ohmeda 3800
    • Datex Ohmeda 3900
    • Datex Ohmeda 3900P
    • Datex Ohmeda 4700
    • Datex Ohmeda 5250 respiratory gas monitors
    • Datex Ohmeda 5250 RGM
    • Datex Ohmeda AS/3
    • Datex Ohmeda Biox 3700e
    • Datex Ohmeda Biox 3740
    • Datex Ohmeda Biox 3760
    • Datex Ohmeda CS/3
    • Datex Ohmeda Modular Monitors with M-OSAT module
    • Datex Ohmeda Modulus CD
    • Datex Ohmeda Oxicap
    • Datex Ohmeda Rascal II
    • Datex Ohmeda S/5
    • Datex Ohmeda TuffSat 3775
    • Datex Ohmeda TuffSat
    • Datex Ohmeda Cardiocap/5
    GE Healthcare > Corometrics
    • GE Healthcare > Corometrics 200SL
    • GE Healthcare > Corometrics 400SL
    • GE Healthcare > Corometrics 511
    • GE Healthcare > Corometrics 600SL
    • GE Healthcare > Corometrics 800A
    • GE Healthcare > Corometrics 800SL
    • GE Healthcare > Corometrics TRAM A.R.
    • GE Healthcare > Corometrics TRAM x00SL Series
    GE Healthcare > Marquette
    • GE Healthcare > Marquette 7000 Series
    Mennen
    • Mennen Horizon XL800 (Ohmeda SpO2)
  • Technical Specifications:

    Specification Value
    Connector Distal Male 9-pin Hypertronix Connector
    SpO2 Technology Ohmeda
    Cable Color Gray
    Cable Diameter (mm) 4 splitting to 2.5*2
    Total Length (cm) 300
    Connector Proximal Multi-Site
    Patient Size All patient sizes
    Cable Material TPU Jacket
    Certifications FDA,CE,ISO10993-1,5,10:2003E,TUV,RoHS Compliant
    Packaging Bag
    Packaging Unit 1
    Latex Free Yes
    Sterile No
    Warranty (months) 12
    Weight (kg) 0.15